Hewlett-Packard Codemaster XL

Be the first to review this product

Availability: In stock

Call for Details
OR

Quick Overview

Hewlett-Packard Codemaster XL

Hewlett-Packard Codemaster XL

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Details

Hewlett Packard Codemaster XL and XL+ defibrillators with a built-in recorder, ECG, and AC power with battery back-up. OPTIONAL * SPO2 - Pulse Oximetry * Pacing * Advisory Mode * External electrode adapters. SPECIFICATIONS * Dimensions 7.9"H x 11.8"W x 15.6"L 20cm x 30cm x 39.7cm * Weight: 24 lbs. / 10.9kg * Battery Type: Rechargeable, sealed lead-acid battery. 4 Ah, 12 V nominal. Charge Time: 2 hours to 90% of full capacity. 18 hours to 100% capacity. Repeated charging to less than 100% will reduce the useful life of the battery. Capacity: 2.5 hours monitoring or 50 full-energy discharges or 1 hour monitoring and recording. AC input: 100 to 230 VAC +/- 15%, 50/60 Hz. Battery Indicators: Illuminated LED indicates battery is charging. Low Battery message appears on the monitor. * Defibrillator Waveform: damped sinusoidal. Output energy (delivered): 2,3,5,7,10,20,30,50,70,100,150,200,300, and 360 joules. Charge control: push-button on apex paddle and on front panel. Charge time: less than 5 seconds to 360 joules with a functional battery installed. Charge done indicator: display indicates available energy, charge-done light on apex paddle, charge done tone. Synchronizer: SYNC message appears on the monitor and is annoted periodically on the recorder while in synchronous mode. An audible beep sounds with each detected R-wave, while a marker on the monitor and sync mark on the recorder strip indicate the discharge point. Paddles: standard paddles are anterior / anterior. Adult electrodes (83 cm sq) slide off to expose pediatric electrodes (21 cm sq). Paddle cord is 10 feet (3m). Full range of internal paddles are available. * Monitor Input: ECG activity may be viewed through the paddles or patient cable. Lead fault: LEADS OFF message and dashed baseline appear on the monitor if a lead becomes disconnected. Common mode rejection: greater than 100dB measured as per AAMI standards for cardiac monitors. Heart rate display: digital read out on monitor from 20 to 280 bpm. * Recorder Annotations: time, date, heart rate, event markers, ECG mode, and selected energy. Recorder Mode: automatically documents events and ECG during defibrillation episodes. The recorder can be configured to run in either real time or with a 6-second delay. Frequency response: .5 to 40Hz monitor bandwidth. .05 to 150 Hz diagnostic bandwidth is selectable.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Contact Monet Medical
Please feel free to contact us about questions you may have.
or call (Phone) (801) 955 7150 (Fax) (801) 955 4898