Products

Monet Medical products

Siemens Servo 300 Ventilator

Be the first to review this product

Availability: In stock

Call for Details
OR

Quick Overview

Siemens Servo 300 Ventilator

Siemens Servo 300 Ventilator

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Details

Ventilator Type: Positive Pressure;Invasive;Conventional Ventilator Class: Intensive Care Unit (ICU);Transport;CPAP Patient Population Range: Neonatal;Pediatric;Adult Features: Customizable respiratory patterns, supported and controlled ventilation modes, easy setup using context-sensitive controls, automatic emergency battery backup. Modes--Invasive: Pressure-controlled modes --- PRESSURE CONTROL, PRESSURE SUPPORT, SIMV (PRESSURE CONTROL) + PRESSURE SUPPORT, PRESSURE REGULATED VOLUME CONTROL, VOLUME SUPPORT, CPAP Flow-controlled modes --- VOLUME CONTROL; SIMV (VOLUME CONTROL) + PRESSSURE SUPPPORT Waveforms: Pressure: Rectangular, Adjustable Slope; Flow: Rectangular, Adjustable Slope Operating Range of Controls: Trigger Sensitivity Level: Pressure: (0 to 20 cmH2O below PEEP); Flow: adult: 0.6 - 2.0 L/min, pediatric: 0.3 - 1.0 L/min, neonate: 0.15 - 0.5 L/min; CMV Frequency: 5 to 150 breaths/min; SIMV Frequency: 0.5 to 40 breaths/min; Pressure Control Level Above PEEP: 0 to 100 cmH2O; Pressure Support Level Above PEEP: 0 to 100 cmH2O; Pause Time: 0% to 30%; Minute Volume: 0.2 to 60 L/min; Inspiratory Time: 10% to 80% of the ventilatory period; Baseline Pressure: 0 to 50 cmH2O Triggering: Pressure, flow, time, manual Graphic Display: Red Digital Display; Power: AC 110V/60Hz Other Characteristics: Also monitors I:E ratio Specifications Front Panel Controls: Patient type (adult, pediatric, neonate); Mode of ventilation; Pressure or flow triggering; Pressure limit; Baseline pressure; Minute volume; Ventilator frequency; Start breath; Pause hold; Inspiratory time (%); Inspiratory pause time (%); Rise time of inspiratory pressure; FIO2; Deliver preset group of 100% oxygen breaths Power Requirements: Electrical power: 115 VAC, 60 Hz; Pneumatic power: Air and oxygen at 29 to 100 psig Alarm Controls: Airway pressure: Pressure > upper pressure limit or set PEEP level plus 15 cmH2O for more than 15 seconds; O2 concentration: FlO2 above or below 6% of the set alarm value or if the oxygen fuel cell is not connected; Exp minute volume alarm: minute volume > set value or < 0.3 L/min for adults and children or 0.06 L/min for neonates. Non-Adjustable Alarms: Battery: main electric power has failed and the ventilator has switched to battery backup; Gas Supply: gas pressure < 29 psig or > than 94 psig; Technical: a wide variety of technical problems, most of which require technical service; Apnea: time between breaths > 10 seconds for adults, 15 seconds for children, or 20 seconds for neonates Other Specifications: 30 minute battery duration. Alarms classified by urgency. Monitored Variables : Pressure peak, mean, pause, baseline, and an analog bar graph of instantaneous airway pressure Respiratory Rate Tidal Volume inspired and expired

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Contact Monet Medical
Please feel free to contact us about questions you may have.
or call (Phone) (801) 955 7150 (Fax) (801) 955 4898